Specific cable / buyer evidence

Document a 15 kV URD surplus reel

“URD” alone does not establish conductor size, insulation, neutral construction or a reel’s remaining length. A Chelan PUD specification provides one concrete 15 kV example; the offered reel must be checked against its own manufacturer print and paperwork.

Submit cable details
Distinct buyer question

Use a real 15 kV URD procurement specimen to gather construction and reel-record evidence.

Checkable specification fields

These are examples from the named references, not assertions about a reel you have not shown us. Match the actual jacket, tag and part number before using a product claim.

FieldDocumented example / boundarySource
Reference constructionChelan’s specified example is 15 kV, #2 or 4/0 aluminum with EPR insulation, LLDPE jacket and copper concentric-neutral wires.[1]
Distinct layersThe reference differentiates semiconducting conductor/insulation shields from the metallic concentric-neutral conductors.[1]
Original packaging exampleChelan requests approximately 2,500-ft reels, sealed ends and jacket sequence marks at 2-ft intervals for that order.[1]
Reel traceabilitySeattle City Light lists manufacturer, shipping footage, end sequences, gross/tare/net weight, date and reel ID among its procurement fields.[2]

Create a construction record, not a generic URD label

Photograph the voltage legend and the exposed, safely disconnected end; list conductor metal/size, insulation, neutral wire construction and jacket. The Chelan specification is a reference profile, not evidence that a different 15 kV reel has the same neutral, insulation or footage.

  • Ask for exact manufacturer and voltage class on jacket and original reel tag.
  • Capture any sequence-number start/end, but do not assume the original length remains.
  • Record neutral-wire count/size if documented; use “unknown” otherwise.

Check a reel’s chain of evidence

A utility procurement list shows what can be traced on an original shipment: maker, purchase reference, weight and certified test report. A seller may not possess all of those. Say which documents exist and which are missing; an original report does not establish today’s end seals or insulation integrity.

  • Photograph both end seals, flange edges and exposed outer layers.
  • Describe storage conditions and visible damage separately from the manufacturer design.

Source notes and scope

The linked references support the specific examples above. Product designs and standards can change; seller-supplied markings, measured length and current condition require separate verification. Nothing here states that this buyer stocks, tests, guarantees or accepts a particular cable, or offers installation advice.

  1. Chelan PUD Standard 5110.0101, specific 15 kV EPR URD procurement
  2. Seattle City Light Material Standard 6015.00