Record a VFD motor-cable reel accurately

A variable-frequency-drive cable can include power conductors, grounds and a metallic shield in one assembly. “Industrial power cable” alone hides those distinctions. This guide uses a specific Southwire specimen to show the fields a seller should verify on the actual reel.

Submit cable details
Distinct buyer question

Differentiate shielded VFD motor cable from ordinary tray cable in industrial-project surplus.

Checkable specification fields

These are examples from the named references, not assertions about a reel you have not shown us. Match the actual jacket, tag and part number before using a product claim.

FieldDocumented example / boundarySource
Manufacturer exampleSouthwire SPEC45451: 2000 V three-conductor copper VFD cable with XLPE RHH/RHW-2 insulation and PVC jacket.[1]
Shield and groundsThat product includes three copper grounds and a copper-tape shield with at least 50% overlap.[1]
Intended contextThe named product is specified between variable-frequency drives and motors; an application example does not qualify a surplus reel.[1]
Project contextSouthwire lists VFD/control cable separately from feeder wire, PV wire and cabinet whips in a data-center cable ecosystem.[2]

Show the entire power assembly

A cut-end photograph should make the conductor count, grounds and shield construction inspectable. Record the exact part number, jacket legend, nominal size and voltage as marked. Southwire’s published 2000 V example is not a rating assigned to every cable called VFD.

  • Transcribe the manufacturer, Type TC-ER/VFD and any voltage wording from this reel.
  • Identify copper/other metal, conductor size/count, separate grounds and shield evidence.
  • Record jacket type and whether the ends show damage or modifications.

Use industrial context only as context

A reel left from a motor-control or data-center project still needs evidence of its own identity, footage and storage. A project description cannot substitute for a datasheet or electrical test; do not use a cited hazardous-location or installation statement as a blanket code-compliance claim.

  • Attach reel ID, tag, measured or qualified length and source document.
  • State that a product-fit inquiry does not guarantee purchase or energized-service suitability.

Source notes and scope

The linked references support the specific examples above. Product designs and standards can change; seller-supplied markings, measured length and current condition require separate verification. Nothing here states that this buyer stocks, tests, guarantees or accepts a particular cable, or offers installation advice.